micro MAXX series

micro MAXX compact amplifiers (µMA01/POE, µMA04/POE, µMA04/M): PoE++ or mains, onboard DSP and Dante/AES67, with the same Maxx Control API and Maxx Remote support.

micro MAXX (MICRO MAXX series) is Innosonix’s compact DSP amplifier family: GaN power stages, onboard loudspeaker management, and flexible Audio over IP (Dante / AES67). Models share the same small chassis and the same control stack as other MAXX amplifiers.

Software path

StepToolUse
1IDFMDiscover the amp, set IP / hostname, update firmware
2Maxx ControlPer-device browser UI and REST API (http://<ip>/)
3Maxx RemoteMulti-amp projects, groups, offline planning

This docs site covers Maxx Control mainly as a REST / integrator reference. Full on-device UI and DSP operator manuals are on the downloads page and product pages; not duplicated here.

Models at a glance

ModelPowerChannelsRated output (EIAJ, 1 kHz, 1% THD)Notes
µMA01/POEPoE / PoE+ / PoE++1200 W @ 4 Ω; 400 W @ 8 Ω; 400 W Hi-ZAlso supports 70 V / 100 V / 16 Ω / 8 Ω operation; full rated power with PoE++ (see below)
µMA04/POEPoE / PoE+ / PoE++4120 W/ch @ 4 Ω and 8 Ω; bridged 240 W @ 8 Ω (2 ch)Full rated power with PoE++ / IEEE 802.3bt; PoE / PoE+ still operate at reduced rated power (see below)
µMA04/MMains (IEC C6, 90–264 VAC)4120 W/ch @ 4 Ω and 8 Ω; bridged 240 W @ 8 Ω (2 ch)Optional rack-mount kit for 1–3 units in 1U

Shared form factor: W 195.25 mm × H 39.00 mm × D 214 mm. Typical weight ≈ 1.25 kg (PoE models) / 1.35 kg (µMA04/M).

All three expose a RESTful API used with Maxx Remote, plus third-party plugins such as Q-SYS and Loxone (same integration story as other Innosonix amps; see Maxx Control third-party plugins).

PoE classes (µMA01/POE, µMA04/POE)

PoE micro MAXX models (µMA01/POE, µMA04/POE) operate on PoE, PoE+, and PoE++ (IEEE 802.3af / at / bt). Lower PoE classes still power the amplifier; they limit how much of the full rated power you can use. Use a PoE++ / IEEE 802.3bt switch or injector when you need the full rated power (for µMA04/POE: 120 W/ch @ 4 Ω and 240 W bridged @ 8 Ω).

µMA04/M is mains-powered (IEC) and is not a PoE model.

Where PoE classes come from

IEEE 802.3 defines power classes so a PSE (Power Sourcing Equipment, typically a PoE switch or injector) and a PD (Powered Device, here the micro MAXX) can negotiate a safe power budget over the Ethernet cable. The class sets two related limits:

  • PSE wattage: maximum power the switch/injector may source at the port
  • PD wattage: maximum power the powered device may draw at the cable end (lower than PSE because of cable loss)

Marketing names map to those IEEE types/classes roughly as follows:

Marketing nameIEEE standardTypeClassesMax at PSEMax at PD
PoE802.3afType 11–315.4 W13 W
PoE+802.3atType 2430 W25.5 W
PoE++802.3btType 35–660 W51 W
PoE++802.3btType 47–890 W71.3 W

Per-class detail (IEEE 802.3):

ClassTypical nameMax PSE powerMax PD power
1PoE4.0 W3.84 W
2PoE7.0 W6.49 W
3PoE15.4 W13 W
4PoE+30 W25.5 W
5PoE++45 W40 W
6PoE++60 W51 W
7PoE++75 W62 W
8PoE++90 W71.3 W

Class 0 is a legacy Type 1 default (treated like Class 3). Type 3/4 (802.3bt) use 4-pair power for the higher classes.

How micro MAXX uses that budget (burst power)

Rated amplifier watts on micro MAXX are audio burst figures (EIAJ-style peaks).

micro MAXX PoE models keep an internal capacitor energy store. In short:

  1. The PoE line recharges that store at up to the negotiated class / PD wattage.
  2. Loudspeaker peaks draw burst power from the capacitors, not directly as a continuous PoE draw equal to the rated audio watts.
  3. Between peaks, the store recharges from the PSE again.

That is why a micro MAXX can deliver high rated audio power while the Ethernet port only offers tens of watts: the cable limits the recharge rate; the capacitors supply the short burst energy for audio.

PoE classes feed a micro MAXX PD; internal capacitors supply audio burst power while recharging at class power

Rack density (µMA04/M)

The rack-mount kit holds one, two, or three µMA04/M units in a single 1U space: up to 12 channels in 1U when three 4-channel units are fitted (each unit 120 W/ch @ 4 Ω / 8 Ω).

Datasheets & brochures

DocumentURL
µMA01/POE datasheetuma01_poe_datasheet.pdf
µMA04/POE datasheetumaxx_poe_datasheet.pdf
µMA04/M datasheetumaxx_m_datasheet.pdf
PoE series brochureumaxx-poe-brochure.pdf
µMA04/M launch brochureµMA04-M Launch brochure
µMA01/POE launch brochureµMA01-POE Launch brochure
Product / series pagemicro-maxx-series
Software & manualsinnosonix.de/downloads
TopicPage
Discover, IP, firmwareIDFM
Per-device REST APIMaxx Control
Multi-amp projectsMaxx Remote
Hardware accessories (e.g. Remote Mute)Hardware